Certified Excellence

We meet and exceed all aviation standards
while ensuring the highest levels of safety,
quality, and sustainability in every process

Aviation Standards

HEAT TREATING
SURFACE ENHANCEMENT
CHEMICAL PROCESSING
NDT
AS9100 REVISION D
ISO 9001:2015
ISO 45001:2018
ISO 14001:2015
HEAT TREATING
SURFACE ENHANCEMENT
CHEMICAL PROCESSING
NDT
AS9100 REVISION D
ISO 9001:2015
ISO 45001:2018
ISO 14001:2015

Sustainability

Wastewater treatment and water recycling facility and Membrane system for filtering and treating wastewater

Scrubber to neutralize acid vapors before venting into the air

Collection and separation of hazardous waste in designated containers and treatment at authorized sites.

Wastewater treatment and water recycling facility and Membrane system for filtering and treating wastewater

Scrubber to neutralize acid vapors before venting into the air

Collection and separation of hazardous waste in designated containers and treatment at authorized sites.

The heart of the lab

Comprehensive Flow Management Possibilities

Monoclonal antibodies

The SPuMP is a 2 ml syringe pump operated by a step-motor. The syringe reservoir is temperature controlled. Up to 4 SPuMP-s can be separately controlled from one main controller. The D-Pump is a diaphragm pump with temperature-controlled 1.2 ml reservoir. It is hydraulically driven by a SPuMP, acting as an accurate hydraulic driver. The Control board, manifold and valve systems enable independent Operation of 4 SPuMPS, each driving two D-Pumps, acting together as a Multiplexed pump, where each D-Pump is operated independently with repeating pumping-refilling SpacePharma’s Fluid management system has concluded 6 tours to the International space station and 3 parabolic flights.

Our Labs

SPmg
Robust, simple system for free-orbit satellite and ISS modules SPmg is a 2U system capable of performing 4 experiments. It is equipped with a 600 microliter stirred reactor, a fluorescence microscope and visible light spectrometer. The lab is a closed system where the waste is stored in a volume-saving manner.


ENVIRONMENT

Temperature: 4-37* °C.
Active heaters are placed in order to prevent liquid freezing.

Pressure: 1 bar.

Radiation: Shielded

Environmental Monitoring:
Temperature reading accuracy: ±0.25 °C.
Pressure reading accuracy: ±2%
Radiation sensor sensitivity: 5.9 cpm/µSv/h


FLUID HANDLING

12 reservoirs of 1 ml each (3 for each experiment) These reservoirs also perform system purging between experiments.

4 mixing chambers – one for each experiment.

Reaction chamber – 600 micro-liters with speed-adjusted stirrer (60-300 RPM).

The reaction chamber is observed by the analytical system.


CHARACTERIZATION CAMERA

Camera:
Color filter array: RGB Bayer pattern.
Bit depth: 10 bit.
Dynamic range: 61 dB.
(Ability to compress to jpg images from raw format)
Active pixels: 2,048H x 1,536V.
Pixel size: 3.2μm x 3.2μm.

Microscope :
Field of view: 1.28 x 0.96 mm2.
Magnification: x5.
Pixel resolution: 0.64 µm.
Depth of field: 25 µm.

Software Controlled Adjustable Focus Step:
size: 10 µm.
Total range: 1300 µm.


CHARACTERIZATION SPECTROMETER

Spectrometer:
Wavelength: 420-750 nm.Optical resolution: 1.5 nm FWHM.

The SPmg has concluded one tour to the ISS. A second unit is active for over two years in a free-orbit satellite.

The heart of the lab

Modern Times

The factory of the futureModern Times is a large capacity system for either performing multiple experiments (as in factorial design tests) or for manufacturing industrial quantities. Design to be flown onboard Unmanned spacecraft.

SPECIFICATIONS

24U – 20*30*40
CMFour production lines
44 flow reactors
Advanced flow handling system with more than 36 pumps
Visible and fluorescence microscopy
Spectrometer and Fluorimeter
Active temperature control with different temperature zones
Advanced communication